Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 172
Filtrar
1.
Int Ophthalmol ; 44(1): 203, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38671195

RESUMO

PURPOSE: This study aimed to observe the tilt and decentration of multifocal intraocular lens (IOL) with optic capture in Berger space within 2 years after pediatric cataract surgery. METHODS: This is a prospective observational study. The implantation of multifocal IOL (Tecnis ZMB00) with optic capture in Berger space was performed on 33 patients (48 eyes) with pediatric cataract at Qingdao Eye Hospital. Tilt and decentration of IOL was measured using Scheimpflug system (Pentacam) at 1 month and 2 years postoperatively. RESULTS: All the multifocal IOLs were successfully implanted in Berger space with optic capture and no visually significant complications were detected during the follow-up. The mean tilt of IOLs was 2.779° ± 0.950° in the vertical plane and 2.399° ± 0.898° in the horizontal plane at 1 month postoperatively, and the mean length of the decentration was 0.207 ± 0.081 mm in vertical plane and 0.211 ± 0.090 mm in the horizontal plane. Compared with 1 month after surgery, the angle of tilt decreased by a mean of 0.192° and decentration increased by a mean of 0.014 mm at the vertical meridian at 2 years postoperatively (P = 0.37 and P = 0.27, respectively), meanwhile, tilt increased by 0.265° and decentration increased by 0.012 mm at the horizontal meridian (P = 0.11 and P = 0.22, respectively). CONCLUSIONS: The follow-up results suggest the tilt and decentration of multifocal IOL implantation with optic capture in Berger space remain stable in an acceptable range within 2 years after cataract surgery in children above the age of 5. TRIAL REGISTRATION: The study was approved by the Ethics Committee of Qingdao Eye Hospital, and registered on Chinese Clinical Trial Registry (ChiCTR identifier: 1900023155).


Assuntos
Extração de Catarata , Catarata , Lentes Intraoculares Multifocais , Acuidade Visual , Humanos , Masculino , Feminino , Estudos Prospectivos , Catarata/complicações , Catarata/fisiopatologia , Pré-Escolar , Criança , Extração de Catarata/métodos , Extração de Catarata/efeitos adversos , Seguimentos , Desenho de Prótese , Migração do Implante de Lente Intraocular/diagnóstico , Migração do Implante de Lente Intraocular/fisiopatologia , Migração do Implante de Lente Intraocular/etiologia , Migração do Implante de Lente Intraocular/cirurgia , Implante de Lente Intraocular/métodos , Lactente
2.
Korean J Ophthalmol ; 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38644651

RESUMO

Purpose: To investigate the clinical outcomes of new hydrophobic trifocal intraocular lens (IOL) with hydroxyethyl methacrylate (HEMA) in the Korean population. Methods: This prospective, multicenter, and observational study evaluated the clinical outcomes of eighty eyes of 40 patients with age-related cataract underwent cataract surgery using CNWT (Clareon PanOptix). Assessment included monocular and binocular uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA at 60cm), near visual acuity (UNVA at 40cm and 33cm), uncorrected defocus curves, questionnaires evaluating photic phenomena, spectacle independence and spectacle free satisfaction. Results: At 3-month postoperatively, mean uncorrected binocular visual acuities were 0.04, 0.04, 0.03 logMAR at far, intermediate, and near distances respectively. All patients achieved uncorrected binocular VAs of 0.2 logMAR or better. Monocular and binocular defocus curve indicated a mean VA of 0.2 logMAR or better at the defocus range of +1.0 D to - 3.0D (100 cm to 33 cm) and +1.0 D to - 3.5 D (100 cm to 28 cm). High spectacle independence was observed at all distances, with 37.5% patients reporting photic phenomena. Conclusions: The Clareon PanOptix IOL has shown positive clinical outcomes, providing a viable option for cataract surgery. These lenses effectively address patients' visual needs, especially in intermediate and near distance tasks, reducing dependence on glasses.

3.
Cesk Slov Oftalmol ; 80(2): 93-102, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38531682

RESUMO

PURPOSE: To compare objective quality of vision in patients undergoing phacoemulsification with implantation of a bilateral segmented multifocal intraocular lens (SMIOL). METHODS: A retro-prospective study included 110 eyes of 55 patients who underwent cataract surgery with bilateral SMIOL implantation. Patients were divided according to the type of implanted intraocular lens into group 1 (SBL-2, 62 eyes) and group 2 (SBL-3, 48 eyes). Postoperatively, monocular and binocular uncorrected distance visual acuity (UCDVA), corrected distance visual acuity (BCDVA), uncorrected intermediate visual acuity (UCIVA, at 66 cm), uncorrected near visual acuity (UCNVA, at 40 cm), corrected near visual acuity (BCNVA) and defocus curve were measured and evaluated. The follow-up period was 6 months. RESULTS: Mean UCDVA in group 1 (SBL-2) was 0.010 ±0.15 LogMAR monocularly, 0.01 ±0.10 LogMAR binocularly, and in group 2 (SBL-3) was 0.02 ±0.11 LogMAR monocularly and -0.07 ±0.09 LogMAR binocularly. Binocular defocus curves showed that the SBL-3 group performed better than the SBL-2 lens at a vergence of -1.50 D corresponding to 66 cm (center distance), averaging 0.03 ±0.11 LogMAR, while the SBL-2 group averaged 0.12 ±0.14 LogMAR (p = 0.01). The -2.50 D vergence characterizing near vision (40 cm) was achieved by the SBL-2 lens in our study at 0.33 ±0.15 LogMAR and by the SBL-3 lens at 0.00 ±0.11 LogMAR (p = 0.00). CONCLUSION: Both SMIOLs provided very good vision at all tested distances 6 months postoperatively. The SBL-2 lens performed better in UCIVA, while the SBL-3 lens excelled in UCDVA and UCNVA.


Assuntos
Lentes Intraoculares , Facoemulsificação , Humanos , Implante de Lente Intraocular , Estudos Prospectivos , Refração Ocular , Acuidade Visual , Desenho de Prótese , Visão Binocular
4.
J Fr Ophtalmol ; 47(4): 104105, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38428321

RESUMO

PURPOSE: To compare the visual outcomes in both eyes of patients who undergo phacoemulsification and trifocal intraocular lens (IOL) implantation and have asteroid hyalosis (AH) or synchysis scintillans (SS) in only one eye. METHODS: A retrospective comparative case series was performed. We evaluated uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA), predictability, safety, efficacy, and satisfaction after implantation of the same model of trifocal IOL in both eyes (PhysIOL FineVision Pod-F and Micro-F and Rayner RayOne Trifocal). RESULTS: A total of 164 eyes of 82 patients (41 females, 50%) met the inclusion criteria. There were no statistically significant differences in sphere, cylinder, spherical equivalent, UDVA, UIVA, or UNVA between the groups. Postoperative CDVA was slightly better in the control group (logMAR 0.03) than in the AH/SS group (logMAR 0.04) (P: 0.014). There were no statistically significant differences in predictability, safety index, or efficacy index between the groups. Overall subjective satisfaction was good (98.2%). CONCLUSIONS: Visual outcomes and satisfaction are good after implantation of trifocal IOLs in eyes with AH or SS. Therefore, trifocal IOLs should not be ruled out in these patients when no other vitreoretinal disorder is present.


Assuntos
Lentes Intraoculares , Doenças Orbitárias , Facoemulsificação , Feminino , Humanos , Facoemulsificação/efeitos adversos , Implante de Lente Intraocular/efeitos adversos , Estudos Retrospectivos , Satisfação do Paciente , Lentes Intraoculares/efeitos adversos , Refração Ocular , Transtornos da Visão , Desenho de Prótese , Pseudofacia/complicações , Pseudofacia/cirurgia
5.
Clin Ophthalmol ; 18: 605-612, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38435374

RESUMO

Purpose: To examine the effect of preoperative angle kappa on patient-reported outcomes after multifocal lens placement during cataract surgery and determine if it is an effective measure for preoperative patients screening for multifocal lens placement. Setting: Private refractive surgery clinics. Design: Retrospective cohort study. Methods: All patients undergoing bilateral cataract or refractive lens exchange surgery with a target of emmetropia between 2013 and 2017 at Optical Express (Glasgow, UK) with multifocal lens placement for whom preoperative angle kappa measurement and a postoperative month 1 patient-reported outcomes measures were available were included. Results: A total of 1368 patients were identified. Median preoperative angle kappa was 0.41mm with an interquartile range of 0.30mm to 0.53mm. Preoperative angle kappa did not have a significant association with patient-reported satisfaction with vision (correlation coefficient 0.15, 95% confidence interval -0.081 to 0.39, P = 0.20) nor with patient-reported photic phenomena (P > 0.09 for all comparisons). A receiver-operator characteristic analysis did not yield a viable cutoff predictive of patient-reported satisfaction. Conclusion: Angle kappa was not predictive of patient-reported satisfaction in this study. This study did not find evidence that it should be used as a screening test for patients considering multifocal intraocular lens placement.

6.
Clin Ophthalmol ; 18: 365-375, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38343905

RESUMO

Purpose: To perform a multimodal assessment of refractive outcomes and quality of vision (QoV) in patients with high myopia submitted to multifocal intraocular lens (IOL) implantation. Methods: Retrospective study that included consecutive eyes with high myopia (axial length [AL] >26.00mm) submitted to multifocal IOL implantation between January 2014 and February 2020. Minimum follow-up time was 3 years. QoV was evaluated with the Objective Scatter Index (OSI) and the Modular Transfer Function (MTF) by HD Analyzer®. Two QoV questionnaires were applied to patients in which both eyes were included: the McAlinden and the Catquest-9 SF. Results: We included 50 eyes (28 patients). The mean follow-up time was 5.4±1.0 years. Comparing to month 1 after surgery, at the last follow-up visit, there was a decrease in the uncorrected visual acuity (0.14±0.13 vs 0.08±0.09 LogMAR, p=0.024), a negative increase in the spherical equivalent (-0.31±0.60 vs -0.02±0.20, p=0.006) and no changes in the best-corrected visual acuity (p>0.999). An uncorrected near visual acuity of at least J2 was achieved in 89% of eyes one month after surgery and in 91% of eyes at the last follow-up visit (p=0.829). At the last follow-up, the mean OSI was 5.1±1.8 and the mean MTF was 17.5±10.6. Some degree of near vision difficulty was reported by 91% of patients, and 74% of patients reported photic phenomena (halos, glare, starbursts). However, most patients reported that these symptoms caused none to little bothersome. At the last follow-up, 87% of patients were at least fairly satisfied with the surgery. Conclusion: Even after a mean follow-up time of 5 years, patients maintained good uncorrected visual acuity. Even though most patients experienced some degree of near vision difficulty and visual symptoms, globally, our patients were satisfied with their current vision, and the experienced symptoms did not have a significant impact on their daily lives.

7.
Graefes Arch Clin Exp Ophthalmol ; 262(2): 367-380, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37278907

RESUMO

PURPOSE: With the aging population, the prevalence of presbyopia and the popularity of multifocal intraocular lenses is also growing worldwide. Unfortunately, in some cases, they are still associated with postoperative visual disturbances. Recent literature started to evaluate angle kappa- and angle alpha-derived metrics of chord mu and chord alpha as possible predictive values for visual outcomes after multifocal intraocular lens implantation but the published results are inconsistent between studies. Thus, this article aims to review the role of chord mu and chord alpha as postoperative predictors after multifocal intraocular lens implantation and lay the foundation for further research. METHODS: Relevant articles were identified using the following keywords: "presbyopia," "multifocal intraocular lens," "angle kappa," "angle alpha," "Chord mu," and "Chord alpha" up to June 2022. An attempt was made to present the majority of publications that addressed the topic. CONCLUSIONS: Chord mu and chord alpha have a predictive role on the outcomes after multifocal intraocular lens implantation but to a different extent. Cataract surgeons should take them into consideration and avoid implanting a multifocal intraocular lens for patients with speculated critical values of chord mu and alpha above 0.5-0.6 mm, depending on the device used for measurement and the multifocal intraocular lens implanted. Currently, chord alpha seems to be a more stable, more widely applicable, and reliable determinant in predicting postoperative outcomes and in patient selection prior to multifocal intraocular lens implantation when compared to chord mu. To draw conclusions on the topic, a controlled study is needed.


Assuntos
Lentes Intraoculares , Lentes Intraoculares Multifocais , Presbiopia , Humanos , Idoso , Implante de Lente Intraocular/métodos , Acuidade Visual
8.
Semin Ophthalmol ; 39(3): 217-222, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37997000

RESUMO

OBJECTIVE: To observe the clinical effect of piggyback multifocal intraocular lens (IOL) implantation in treating patients with high myopia complicated with cataract. METHODS: This was a prospective controlled study. We compared 32 eyes of 32 patients who underwent femtosecond laser-assisted cataract surgery with piggyback IOL implantation (two IOLs were implanted into the capsule) with 32 eyes of 32 patients who also underwent the same surgery (one IOL implanted into the capsule) due to high myopia complicated with cataract at the Wuhan Aier Eye Expert Hospital between January 2019 and October 2020. All patients were followed up for three months after surgery. Uncorrected distance visual acuity (UCDVA), uncorrected intermediate visual acuity (UCIVA), uncorrected near visual acuity (UCNVA), best-corrected distance visual acuity, distance-corrected intermediate visual acuity (DCIVA), distance-corrected near visual acuity (DCNVA), postoperative spectacle independence, postoperative visual interference, equivalent spherical lens, defocus curve, and IOL tilt and eccentricity were evaluated. RESULTS: Three months after surgery, the patients' UCIVA, UCNVA, DCIVA, and DCNVA were 0.49 ± 0.07, 0.38 ± 0.15, 0.47 ± 0.09, and 0.36 ± 0.12, respectively, in the research group and 0.56 ± 0.18, 0.72 ± 0.22, 0.55 ± 0.13, and 0.69 ± 0.15, respectively, in the control group; the differences between the two groups were statistically significant (P < .05). The spectacle independence rate was higher in the research group (93%) than in the control group (13%). The overall satisfaction regarding postoperative visual quality was also higher in the research group than in the control group. The absolute mean value of the spherical equivalents was 0.48 ± 0.28 D in the research group and 0.62 ± 0.33 D in the control group; the difference between the two groups was statistically significant (P < .05). CONCLUSION: Piggyback multifocal IOL implantation can expand the multifocal IOL application range, and satisfy the desire of patients with high myopia complicated with cataract to see both near and far.


Assuntos
Extração de Catarata , Catarata , Lentes Intraoculares , Miopia , Facoemulsificação , Humanos , Implante de Lente Intraocular , Estudos Prospectivos , Catarata/complicações , Miopia/complicações , Miopia/cirurgia , Desenho de Prótese
9.
International Eye Science ; (12): 106-110, 2024.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1003516

RESUMO

AIM: To compare the short-term postoperative visual acuity, visual disturbance phenomena, and spectacle independence rate in patients who underwent monocular implantation with trifocal, multifocal, or extended range of vision intraocular lens(IOL).METHODS: A retrospective analysis was conducted on 67 cataract patients(67 eyes)who underwent phacoemulsification cataract extraction combined with IOL implantation from March 2019 to December 2022. A total of 35 cases(35 eyes)received Symfony extended range of vision IOL implantation, 21 cases(21 eyes)received AcrySof IQ ReSTOR +3D multifocal IOL, and 11 cases(11 eyes)received AcrySof IQ PanOptix trifocal IOL. The preoperative uncorrected distance visual acuity(UDVA), uncorrected intermediate visual acuity(UIVA), and uncorrected near visual acuity(UNVA)and 3 mo postoperatively were documented. Moreover, defocus curves, visual disturbance phenomena, and spectacle independence rates were recorded at 3 mo postoperatively.RESULTS: At 3 mo postoperatively, no statistically significant differences were observed in UDVA among the three groups(P&#x0026;#x003E;0.05). A comparison of UIVA showed superior results in the Symfony and PanOptix groups compared to the ReSTOR group(all P&#x0026;#x003C;0.01). The UNVA of both the ReSTOR and PanOptix groups outperformed the Symfony group(all P&#x0026;#x003C;0.01). The defocus curves indicated that in the intermediate vision range(-1.00 to -1.50 D), the Symfony group exhibited better performance than the ReSTOR group(P&#x0026;#x003C;0.05); while in the near vision range(-2.50 to -3.50 D), the ReSTOR group was superior to the Symfony group(P&#x0026;#x003C;0.05). The PanOptix group demonstrated superior visual acuity in the near vision range(-2.00 to -3.50 D)compared to the Symfony group(P&#x0026;#x003C;0.05)and was also superior in the intermediate vision range(-1.00 to -2.00 D)compared to the ReSTOR group(P&#x0026;#x003C;0.05). No significant differences were observed in the incidence of glare or halo and binocular interference phenomena among the three groups(P&#x0026;#x003E;0.05). The PanOptix and ReSTOR groups exhibited a higher spectacle independence rate compared to the Symfony group(P&#x0026;#x003C;0.0167).CONCLUSION: Compared to Symfony extended range of vision IOL and ReSTOR multifocal IOL, PanOptix trifocal IOL offers a balanced approach to distance, intermediate, and near visual acuity, without a high incidence of glare and halo, and with a higher spectacle independence rate. Caution is still advised when considering monocular implantation with presbyopia-correcting IOLs.

10.
Front Med (Lausanne) ; 10: 1214714, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38089878

RESUMO

Purpose: To investigate the effects of postoperative astigmatism on the visual outcomes following presbyopia-correcting surgery with multifocal intraocular lens implantation. Methods: A comprehensive literature search was conducted using PubMed, Embase, and Web of Science for articles published until January 2023. Additionally, we included retrospective case series and prospective comparative studies. The combined mean difference (MD) with 95% confidence intervals (CI) and odds ratio (OR) with 95% CI were used to express continuous and categorical outcomes, respectively. All statistical analyses were performed using Review Manager (version 5.4.1). Results: We included nine eligible studies that analyzed 3,088 eyes. The proportion of eyes with useful postoperative visual acuity (logMAR ≤ 0.20) and residual astigmatism significantly differed with respect to the magnitude of astigmatism and presence/absence of blurred vision (p < 0.001 for both). Additionally, the mean uncorrected distance visual acuity (MD, 0.14; 95% CI, 0.06 to 0.21; p = 0.0003) and uncorrected intermediate visual acuity (MD, 0.07; 95% CI, 0.00 to 0.13; p = 0.04), but not the uncorrected near visual acuity (MD, 0.02; 95%CI-0.01 to 0.05; p = 0.17), significantly differed according to the magnitude of astigmatism. Conclusion: Astigmatism, even at low levels (≥ 0.5D), has a significant effect on visual outcomes, especially on UDVA and UIVA, following multifocal intraocular lens implantation. Accurate preoperative and postoperative evaluation of astigmatism is important.

11.
Oman J Ophthalmol ; 16(3): 482-488, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38059085

RESUMO

AIM: This aims to study visual satisfaction and spectacle independence in prepresbyopic age patients with cataracts after the implantation of either monofocal intraocular lens (IOL) with enhanced intermediate vision or trifocal IOL. SETTING: Private practice. MATERIALS AND METHODS: This prospective, observational case study was conducted on patients in the prepresbyopic age group with cataracts. Patients were allocated to one of the two groups. Thirteen patients (26 eyes) received monofocal IOL with enhanced intermediate vision (intermediate vision group), and 12 patients (24 eyes) received diffractive multifocal IOLs (trifocal group). Uncorrected distance visual acuity (UDVA) and corrected distance visual acuity, Uncorrected intermediate visual acuity (UIVA) and uncorrected near visual acuity (UNVA) values, defocus curves, and contrast sensitivities (CS) of the two groups were compared 3 months' postsurgery. Their spectacle independence and visual satisfaction were also assessed. RESULTS: The study patients were aged 35-45 years and comprised 14 males and 11 females. No significant difference was observed in UDVA (intermediate vision group: 0.02 ± 0.01, trifocal group: 0.02 ± 0.01; P = 0.22) and UIVA (intermediate vision group: 0.20 ± 0.10, trifocal group: 0.19 ± 0.10; P = 0.12). However, a statistically significant difference was observed between the groups in terms of UNVA (intermediate vision group: 0.32 ± 0.10, trifocal group: 0.80 ± 0.10; P = 0.01). The mean CS in monofocal IOL with enhanced intermediate vision and trifocal groups were 1.577 ± 0.3 and 1.550 ± 0.2, respectively (P = 0.40). None of the patients experienced photic phenomena. In total, 10 of 13 patients in the monofocal IOL with enhanced intermediate vision group required spectacle correction for near visual acuity in the range of +1.00 to +2.00 D. CONCLUSION: This study found that there was no significant difference in distance and intermediate vision between the two groups. However, the trifocal group had better uncorrected near vision compared to the monofocal group that had enhanced intermediate vision. The conclusion is that using trifocal IOLs for both eyes provided complete independence from wearing glasses. In addition, no visual disturbances were observed after implanting the new-generation trifocal IOLs.

12.
Adv Ophthalmol Pract Res ; 3(1): 39-46, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37846431

RESUMO

Purpose: To investigate the influence of posterior corneal astigmatism on the prediction accuracy of toric multifocal intraocular lens (IOL) calculation. Methods: The keratometric astigmatism measured by Lenstar LS 900 (KCAL), keratometric astigmatism (KCAP) and total corneal astigmatism (TCA) measured by Scheimpflug camera (Pentacam HR) were documented and analyzed accordingly. Three deduction models using different parameters were compared. Model 1: KCAL â€‹+ â€‹keratometric corneal surgically induced astigmatism (KCSIA, 0.30 D @ 50°); Model 2: KCAP â€‹+ â€‹KCSIA); Model 3: TCA â€‹+ â€‹total CSIA (TCSIA, 0.23 D @ 50°). The prediction errors of each model as the difference vector between the actual and the intended residual astigmatism were compared. Results: Seventy-six eyes implanted with toric multifocal IOLs were included in this study. The vector differences of the actual KCSIA and TCSIA were statistically significant in the total sample and against-the-rule (ATR) subgroup (both P â€‹< â€‹0.05). Model 1 deduced the smallest mean values of prediction error, while that of Model 3 were smaller than that of Model 2, both in the total sample and the ATR subgroups (all P â€‹< â€‹0.05). Meanwhile, in the total sample and ATR subgroups, the centroid vector magnitudes of Model 3 were smaller than that of Model 1 (0.31 â€‹± â€‹0.76 D and 0.39 â€‹± â€‹0.76 D). Conclusions: The calculation of toric multifocal IOL should be individualized especially in the ATR eyes for the impact of PCA on the estimation of the preoperative corneal astigmatism and the CSIA.

13.
Bioengineering (Basel) ; 10(9)2023 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-37760095

RESUMO

The incidence of both cataract and glaucoma is increasing globally. With increasing patient expectation and improved technology, premium intraocular lenses (IOLs), including presbyopia-correcting and toric IOLs, are being increasingly implanted today. However, concerns remain regarding the use of premium IOLs, particularly presbyopia-correcting IOLs, in eyes with glaucoma. This systematic review evaluates the use of premium IOLs in glaucoma. A comprehensive search of the MEDLINE database was performed from inception until 1 June 2023. Initial search yielded 1404 records, of which 12 were included in the final review of post-operative outcomes. Studies demonstrated high spectacle independence for distance and good patient satisfaction in glaucomatous eyes, with positive outcomes also in post-operative visual acuity, residual astigmatism, and contrast sensitivity. Considerations in patient selection include anatomical and functional factors, such as the type and severity of glaucomatous visual field defects, glaucoma subtype, presence of ocular surface disease, ocular changes after glaucoma surgery, and the reliability of disease monitoring, all of which may be affected by, or influence, the outcomes of premium IOL implantation in glaucoma patients. Regular reviews on this topic are needed in order to keep up with the rapid advancements in IOL technology and glaucoma surgical treatments.

14.
Eur J Ophthalmol ; : 11206721231201561, 2023 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-37770020

RESUMO

BACKGROUND: This study aimed to compare visual results following the implantation of two distinct diffractive trifocal IOLs utilizing various vision evaluation techniques and subjective satisfaction. METHODS: The study included 32 eyes receiving AcrySof IQ PanOptix implantation and 32 receiving AT LISA tri 839 MP. Post-operative examination at one year included uncorrected visual acuity (UCVA), distance-corrected visual acuity (DCVA) at 4 m, 80 cm, 60 cm, and 40 cm, Contrast sensitivity under photopic and mesopic conditions, and a questionnaire on subjective quality of vision, optical phenomena, and spectacle independence. RESULTS: The two groups were similar in baseline demographics, pre-operative visual, biometric data (except for axial length), and surgical paraments. The PanOptix outperformed the AT LISA tri in the intermediate range when using the standard visual acuity testing (UCVA: 0.23 ± 0.14 logMAR vs. 0.31 ± 0.17 logMAR, p = 0.04; BCVA: 0.21 ± 0.12 vs. 0.28 ± 0.14, p = 0.03) and in the intermediate and far range when using the interactive computer program (intermediate: UNVA "E" optotype test: 0.05 ± 0.12 vs. 0.12 ± 0.13, p = 0.03; Far: UNVA "E" optotype: 0.07 ± 0.12 vs. 0.13 ± 0.10, p = 0.05). In addition, the PanOptix group had higher contrast sensitivity under photopic and mesopic conditions with and without glare at all spatial frequencies. There was no difference in subjective outcomes between the groups. CONCLUSIONS: Patients who received PanOptix IOL had better visual outcomes for intermediate and far with higher contrast sensitivity under various conditions. Based on patients ' needs and demands, these results could support discussion when tailoring the optimal multifocal IOl.

15.
Int Ophthalmol ; 43(12): 4621-4629, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37715824

RESUMO

PURPOSE: To assess the visual quality after implantation of a rotationally asymmetric multifocal intraocular lens (IOL) using a new method according to the angle kappa. SETTING: Qingdao Eye Hospital, Qingdao, China. DESIGN: Prospective case series. METHODS: Patients with the implantation of SBL-3 IOLs for age-related cataract from September to December 2019 had the distance-horizontal zone of the IOL placed at the center of the optic axis using the Callisto Eye System. Postoperative visual acuities and defocus curves were recorded. Modulation transfer function cutoff frequency, Strehl ratio, and objective scatter index were measured using the Optical Quality Analysis System. The decentration and tilt of IOLs were analyzed by iTrace aberrometry and anterior segment optical coherence tomography. A questionnaire of patient satisfaction was also collected. RESULTS: Thirty patients (60 eyes) were involved, with a balanced sex ratio. Their average age was 56.04 ± 10.83 years. The average angle kappa distance was 0.23 ± 0.121 mm. At 3 months after surgery, the mean uncorrected and corrected distance visual acuities were 0.01 ± 0.07 logMAR and 0.01 ± 0.06 logMAR. The uncorrected intermediate and near visual acuities were 0.09 ± 0.11 logMAR and 0.09 ± 0.11 logMAR. The mean horizontal and vertical tilts of IOLs were 0.67 ± 0.52 degrees and 0.47 ± 0.32 degrees. The mean decentration of IOLs was 0.17 ± 0.08 mm. Most patients were satisfied with their distance, intermediate, and near vision. There was mild glare in 58.3% of the eyes. CONCLUSIONS: Locating the center of the optic axis in the distance-horizontal zone during the implantation of SBL-3 IOLs could provide satisfactory visual acuity and quality.


Assuntos
Lentes Intraoculares , Lentes Intraoculares Multifocais , Facoemulsificação , Humanos , Pessoa de Meia-Idade , Idoso , Implante de Lente Intraocular/métodos , Acuidade Visual , Satisfação do Paciente , Desenho de Prótese , Pseudofacia
16.
Arch. Soc. Esp. Oftalmol ; 98(9): 507-520, sept. 2023. tab
Artigo em Espanhol | IBECS | ID: ibc-224812

RESUMO

La cirugía de cristalino transparente (RLE) permite corregir las ametropías y la presbicia mediante el reemplazo del cristalino por una lente intraocular (LIO), ya sea monofocal, multifocal (MIOL) o de profundidad de foco extendida (EDOF). El desprendimiento de retina (DR) es uno de los eventos adversos más graves tras la RLE. El objetivo de este estudio fue revisar la evidencia y los resultados clínicos relacionados con el riesgo de DR después de la RLE. Se realizó una búsqueda utilizando PubMed y un procedimiento de bola de nieve para identificar estudios originales y series de casos. Según la bibliografía, los pacientes < 60 años con longitudes axiales > 23 mm tienen el mayor riesgo de DR. Solo nueve artículos reportaron la agudeza visual (AV) tras el DR en RLE, y solo 25% de los ojos mostraron una AV > 20/40. Teniendo en cuenta que la disminución de la AV tras el DR se puede dar con todos los tipos de LIO independientemente de su diseño óptico, la actitud más acertada al realizar una RLE sería una cuidadosa selección del paciente, evitando aquellos ojos con factores de riesgo para DR (AU)


Refractive lens exchange (RLE) allows to correct ametropias and presbyopia by replacing the crystalline lens with a monofocal, extended depth of focus or multifocal intraocular lens (IOL). Retinal detachment (RD) is one of the most serious adverse events after RLE. This study aimed to review the evidence related to the risk of RD after RLE and its clinical outcomes. A search using PubMed and a snowball search approach was conducted to identify articles and case reports. According to the literature, patients <60 years old with axial lengths >23 mm have the higher postoperative risk of RD. Only nine articles reported visual acuity (VA) after RD in RLE, and only 25% of eyes had a VA>20/40. Considering that the decrease in VA might be uniform for all types of IOLs after RD, surgeons should focus on preventing the RD by means of selecting the appropriate patient, rather than choosing on a particular IOL optical design (AU)


Assuntos
Humanos , Implante de Lente Intraocular/efeitos adversos , Descolamento Retiniano/etiologia , Lentes Intraoculares Multifocais , Acuidade Visual
17.
Artigo em Inglês | MEDLINE | ID: mdl-37641668

RESUMO

Background: Implantation of multifocal intraocular lenses (IOLs) is becoming increasingly popular for the treatment of visual demands at various distances in patients undergoing phacoemulsification cataract surgery. We aimed to assess the visual performance and rates of photic phenomena, posterior capsule opacification (PCO), and spectacle independence in patients with bilateral implantation of the AcrySof® IQ PanOptix® multifocal IOL model TFNT00 at one and six months postoperatively. Methods: This prospective interventional cohort study included adult patients who underwent uneventful phacoemulsification cataract surgery with bilateral implantation of AcrySof® IQ PanOptix® IOL. Uncorrected and corrected visual acuities at far, intermediate, and near distances were measured preoperatively and at the one- and six-month postoperative follow-up examinations. The rates of photic phenomena, postoperative need for near and distance spectacles, and PCO were also recorded. Results: We included 164 eyes of 82 patients with a male-to-female ratio of 38 (46.3%) to 44 (53.7%) and a mean (standard deviation [SD]) age of 52.37 (7.62) years. There were statistically significant improvements in the visual acuities of both eyes across all distances at the one- and six-month follow-up examinations compared to the preoperative values (all P < 0.001), except for corrected near visual acuity in the right eye (P > 0.05) at six-month. We also detected significant postoperative improvements in visual acuities of both eyes across all distances at the six-month follow-up compared to values at the one-month follow-up (all P < 0.05), except for corrected near visual acuity in the right eye (P > 0.05). The photic phenomenon was reported by 12 (14.6%) of the 82 patients at the six-month postoperative follow-up. Five (6.1%) and eight (9.8%) of the 82 patients reported using spectacles for distance and near, respectively. Additionally, PCO developed in 19 (11.6%) of the 164 included eyes, although it was not clinically significant at six months. Conclusions: The AcrySof® IQ PanOptix® IOL model TFNT00 is recommended for use, given its excellent performance in all ranges of vision, a high rate of spectacle independence, and a good safety profile. Future comparative studies with longer follow-up periods are warranted to verify superiority of its performance over that of other available multifocal IOLs.

18.
Eye Vis (Lond) ; 10(1): 32, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37525263

RESUMO

BACKGROUND: This study aims to detect alterations in the spatio-chromatic pseudophakic vision produced by multifocal diffractive intraocular lenses (IOLs) and provides a physical interpretation. METHODS: In vitro characterization of the imaging performance of two diffractive IOLs: AT LISA Tri (Zeiss) and FineVision (PhysIOL) in on-bench model eye illuminated with red (R, 625 nm), green (G, 530 nm) and blue (B, 455 nm) lights. We used the metrics: energy efficiency (EE), area under the modulation transfer function, longitudinal chromatic aberration (LCA), and halo intensity. Through-focus (TF) analysis and calculation of the expected defocus curve under white (W) daylight were included. In vivo visual acuity (VA) of 50 pseudophakics (60 eyes) was assessed under W, R, G, B lights at far and near. Two clinical experiments evaluated LCA and R, G, B TF-EE effects on pseudophakic vision and their relative importance. RESULTS: Clinical mean VA values under W light agreed with the predicted values at far and near for both IOLs. LCA measurements and R, G, B TF-EE curves were consistent with their lens design based on the 0th and 1st diffraction orders operative for far and near vision, respectively. LCA effects were compensated at near but noticed at far (- 0.75 D under B light). We detected strong asymmetry in visual resolution depending on the object distance and the illuminating wavelength-red predominance at far, blue predominance at near-in consistency with the TF-EE measurements. CONCLUSIONS: Diffractive multifocal IOL designs produce asymmetries in the spatio-chromatic vision of pseudophakics beyond the alterations strictly due to LCA. VA asymmetry for far/near object distance under R and B illumination is clinically detectable in subjects implanted with IOLs with 0th and 1st diffraction orders for far and near vision, respectively. Such VA asymmetry cannot be explained solely from the influence of defocus, as would be derived from a chromatic difference of power, but mainly from the wavelength dependence of the EE.

19.
J Clin Med ; 12(13)2023 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-37445358

RESUMO

The primary objective of this study was to objectively compare the visual performance of patients following premium pseudophakic presbyopia corrections in different light combinations for near- and intermediate-vision activities of daily living (ADLs). This is a prospective, comparative study. A total of 75 patients populated three study groups: G1-patients with bilateral trifocal implantation, G2-patients with bilateral bifocal implantation, and G3-patients with bilateral monofocal implantation. All participants addressed 10 ADLs in nine combinations of light temperature (3000 K, 4000 K, and 6000 K) and light intensity (25 fc, 50 fc, and 75 fc) and declared their subjectively optimal light combination while reading. G2 and G3 had the best total ADL scores in 6000 K/75 fc, while G1 had the best total ADL score in 4000 K/75 fc. Total ADL, easy ADL, and moderate difficulty ADL scores were significantly better in G2, while difficult ADL score was significantly better in G1. The majority of all groups selected 6000 K/75 fc as the most comfortable light combination, and no group selected 3000 K and 25 fc. In conclusion, trifocal patients benefit from intense daylight, while bifocal and monofocal patients benefit from intense, cold lighting. Trifocal patients present superior near-vision capacity in difficult near-vision daily tasks, while bifocal patients present superiority in easy and moderate-difficulty ADLs.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...